Gas Specifications
Model | Framing Dimensions | Viewing Area | BTUs (NG) | AFUE / P.4 (NG Efficiency) |
Weight* | |
---|---|---|---|---|---|---|
Hi | Low | |||||
Abbot | 20-1/4” H x 27” W x 15” D – Premiere 20-1/4” H x 27” W x 16-1/4” D – Deluxe |
16” H x 25” W
|
26,000
|
10,500
|
68.3 %
|
115 lbs.
|
Newcomb |
33-1/2” H x 38” W x 15-1/2” D
|
15” H x 32-1/2” W
|
21,000
|
13,000
|
65.1 %
|
115 lbs.
|
Palisade | 32” H x 39-1/2” W x 10-7/8” D |
15” H x 32-1/2” W
|
20,000
|
13,000
|
63.45%
|
105 lbs.
|
Austin | 39” H x 70-1/2” W x 17 1/2” D |
18-1/2” H x 62-3/4” W
|
38,000
|
27,000
|
69.10%
|
240 lbs.
|
Stanford | 39” H x 58-1/2” W x 17-1/2” D |
18-1/2” H x 52-3/4” W
|
36,000
|
21,250
|
68.75%
|
200 lbs.
|
Bennett | 39” H x 44-1/4” W x 16-1/2” D |
16-1/2” H x 42” W
|
30,000
|
22,000
|
69.5%
|
170 lbs.
|
Langley | 32-1/2” H x 36” W x 8-3/4” D |
12” H x 29-1/2” W
|
15,500
|
11,000
|
64.91%
|
90 lbs.
|
Bradley | 32-1/2” H x 36” W x 15” D |
16-1/2” H x 29” W
|
19,000
|
13,500
|
64.13%
|
110 lbs.
|
Thompson | 37” H x 38” W x 15” D |
16-1/2” H x 29” W
|
26,000
|
18,000
|
67.68%
|
125 lbs.
|
Tahoe | 31” H x 47-1/4” W x 16” D |
14-1/2” H x 39” W
|
40,500
|
29,000
|
Not applicable
outdoor model |
110 lbs.
|
Model |
Venting**
|
Ceiling /
Mantle Height |
Abbot |
3” flex vent on exhaust side
3” flex vent on the air intake side |
Mantle Height = minimum 33” with a 4” deep mantle
Please see manual for other mantle clearances |
Newcomb |
4” flex vent on exhaust side
7” flex vent on the air intake side |
Internal ceiling = minimum 48”
Mantle Height = minimum 40” |
Palisade |
4” flex vent on exhaust side
7” flex vent on the air intake side |
Internal ceiling = minimum 40”
Mantle Height = minimum 40” |
Austin |
4” flex vent on exhaust side
7” flex vent on the air intake side |
Internl ceiling = 58” from top of unit
Mantel height = 45” |
Stanford |
4” flex vent on exhaust side
7” flex vent on the air intake side |
Internal ceiling = 58”
Mantle height = minimum 45” |
Bennett |
4” flex vent on exhaust side
7” flex vent on the air intake side |
Internal ceiling = 58”
Mantle height = minimum 42” |
Langley |
3” flex vent on exhaust side
6” flex vent on the air intake side |
Internal ceiling = 40”
|
Bradley |
3” flex vent on exhaust side
5” flex vent on the air intake side |
Internl ceiling= 40” from top of unit
Mantel height=42” |
Thompson |
4” flex vent on exhaust side
7” flex vent on the air intake side |
Internl ceiling= 52” from top of unit
Mantel height=42” |
Tahoe |
No venting required
|
Internal ceiling = 48”
Mantle height = 42” |
**Venting – Any certified 2 ply flex piping can be used. Certified on Duravent, Selkirk, Metal Fab, ICC